Product Overview of Thermometer Calibration Device
NM-TWJ Thermometer Calibration System is mainly used for calibration of non-contact infrared body temperature measuring instruments, such as infrared ear thermometer and infrared forehead thermometer, as well as verification of glass thermometer and medical electronic thermometer. This product is a high-precision auto-control digital temperature calibration device, with the characteristics of good temperature stability, uniform temperature field, high temperature control accuracy, low noise, good reliability and long service life. The device adopts PID for temperature regulation to realize automatic temperature control. It is of compact structure, easy to operate and shows indicating value intuitively. This product is suitable for the calibration and use of non-contact infrared body thermometer by manufacturers, measuring units, medical and health departments, etc. The performance index of the high-precision thermostatic source matched with this product conforms to the verification regulation for glass thermometers and medical electronic thermometers.
Features of Thermometer Calibration Device
1. The thermostatic bath for calibration of NM-RTS05TB thermometer is a thermostatic source specially designed for calibrating the thermometer. Its volume is only 1/2 of an ordinary thermostatic bath. Thus, it is easy to carry and move. Totally-enclosed environment-friendly compressor refrigeration system, without CFC.
2. The latest generation of integrated PID automatic temperature control program and the high-precision Pt100 temperature sensor are built in. A touch screen operation panel is provided, and it is easy to operate with high digital display resolution to ensure accurate and stable temperature control.
3. The high uniformity of flow field and temperature field in the bath is realized by using the side stirring circulation system.
4. The exterior of the black body cavity is plated, and the interior is covered with a black body coating of high emissivity to ensure high black body emissivity and long service life.
5. The anti-aging electrostatic spraying technology is applied to the body shell, and the high-quality S304 stainless steel is used for the inner bath.
6. The shell with fine workmanship and unique humanized design structure are convenient for operators to use.
System Configuration Table
|
Product Model Selection |
Calibration of infrared ear thermometer |
Calibration of infrared forehead thermometer |
Calibration of glass thermometer |
Calibration of electronic thermometer |
|
NM-RTS05TB Thermostatic Bath |
■ |
■ |
■ |
■ |
|
NM-HTB01 Forehead Thermometer Black Body Cavity |
|
■ |
— |
— |
|
NM-HTB02 Ear Thermometer Black Body Cavity |
■ |
|
— |
— |
|
Second-class Standard Platinum Resistance Thermometer |
■ |
■ |
□ |
□ |
|
Standard Thermometer |
— |
— |
— |
■ |
|
High Precision Thermometer |
■ |
■ |
□ |
□ |
|
Reading Telescope |
— |
— |
■ |
□ |
|
Reading Microscope |
— |
— |
■ |
— |
|
Magnifying Lens |
— |
— |
■ |
— |
|
Centrifuge |
— |
— |
■ |
— |
|
Water Triple-point Bottle |
— |
— |
■ |
□ |
■ indicates standard equipment
□ indicates optional equipment
25 — indicates equipment not required
Technical Parameters
|
Temperature range |
-20℃~ 100℃ |
|
Display resolution |
0.001℃ |
|
Temperature uniformity |
0.01℃ |
|
Temperature fluctuation |
0.01℃ |
|
Tank depth |
400mm |
|
Ear temperature blackbody emissivity |
≧ 0.999 |
|
Forehead temperature blackbody emissivity |
≧ 0.997 |
|
Ear temperature black body cavity opening |
Φ10mm |
|
Forehead temperature black body cavity opening |
Φ50mm |
|
Power supply |
220VAC 50Hz |
|
Power |
2kW |
|
Working medium |
Special refrigerant |
|
Dimensions |
500×430×600mm |
|
Net weight |
About 50kg |
According to regulations
|
Code of regulations (standards) |
Name of regulations (model) |
|
JJF1107-2003 |
Calibration specification for infrared thermometers for measuring human body temperature |
|
JJG1164-2019 |
Verification procedures for infrared ear thermometers |
|
JJG1162-2019 |
Verification procedures for medical electronic thermometers |
|
JJG111-2019 |
Verification procedures for glass thermometers |
- 产品描述
-
- Commodity name: NM-TWJ Thermometer Calibration System / Thermometer Calibration Device
NM-TWJ Thermometer Calibration System is mainly used for calibration of non-contact infrared body temperature measuring instruments, such as infrared ear thermometer and infrared forehead thermometer, as well as verification of glass thermometer and medical electronic thermometer.



Product Overview of Thermometer Calibration Device
NM-TWJ Thermometer Calibration System is mainly used for calibration of non-contact infrared body temperature measuring instruments, such as infrared ear thermometer and infrared forehead thermometer, as well as verification of glass thermometer and medical electronic thermometer. This product is a high-precision auto-control digital temperature calibration device, with the characteristics of good temperature stability, uniform temperature field, high temperature control accuracy, low noise, good reliability and long service life. The device adopts PID for temperature regulation to realize automatic temperature control. It is of compact structure, easy to operate and shows indicating value intuitively. This product is suitable for the calibration and use of non-contact infrared body thermometer by manufacturers, measuring units, medical and health departments, etc. The performance index of the high-precision thermostatic source matched with this product conforms to the verification regulation for glass thermometers and medical electronic thermometers.
Features of Thermometer Calibration Device
1. The thermostatic bath for calibration of NM-RTS05TB thermometer is a thermostatic source specially designed for calibrating the thermometer. Its volume is only 1/2 of an ordinary thermostatic bath. Thus, it is easy to carry and move. Totally-enclosed environment-friendly compressor refrigeration system, without CFC.
2. The latest generation of integrated PID automatic temperature control program and the high-precision Pt100 temperature sensor are built in. A touch screen operation panel is provided, and it is easy to operate with high digital display resolution to ensure accurate and stable temperature control.
3. The high uniformity of flow field and temperature field in the bath is realized by using the side stirring circulation system.
4. The exterior of the black body cavity is plated, and the interior is covered with a black body coating of high emissivity to ensure high black body emissivity and long service life.
5. The anti-aging electrostatic spraying technology is applied to the body shell, and the high-quality S304 stainless steel is used for the inner bath.
6. The shell with fine workmanship and unique humanized design structure are convenient for operators to use.
System Configuration Table
Product Model Selection
Calibration of infrared ear thermometer
Calibration of infrared forehead thermometer
Calibration of glass thermometer
Calibration of electronic thermometer
NM-RTS05TB Thermostatic Bath
■
■
■
■
NM-HTB01 Forehead Thermometer Black Body Cavity
■
—
—
NM-HTB02 Ear Thermometer Black Body Cavity
■
—
—
Second-class Standard Platinum Resistance Thermometer
■
■
□
□
Standard Thermometer
—
—
—
■
High Precision Thermometer
■
■
□
□
Reading Telescope
—
—
■
□
Reading Microscope
—
—
■
—
Magnifying Lens
—
—
■
—
Centrifuge
—
—
■
—
Water Triple-point Bottle
—
—
■
□
■ indicates standard equipment
□ indicates optional equipment
25 — indicates equipment not required
Technical Parameters
Temperature range
-20℃~ 100℃
Display resolution
0.001℃
Temperature uniformity
0.01℃
Temperature fluctuation
0.01℃
Tank depth
400mm
Ear temperature blackbody emissivity
≧ 0.999
Forehead temperature blackbody emissivity
≧ 0.997
Ear temperature black body cavity opening
Φ10mm
Forehead temperature black body cavity opening
Φ50mm
Power supply
220VAC 50Hz
Power
2kW
Working medium
Special refrigerant
Dimensions
500×430×600mm
Net weight
About 50kg
According to regulations
Code of regulations (standards)
Name of regulations (model)
JJF1107-2003
Calibration specification for infrared thermometers for measuring human body temperature
JJG1164-2019
Verification procedures for infrared ear thermometers
JJG1162-2019
Verification procedures for medical electronic thermometers
JJG111-2019
Verification procedures for glass thermometers
Key words:- NM-TWJ