NM-HUMI700 Standard ventilation psychrometer
Key words:
Product Description
Product Overview
Standard ventilation psychrometer is designed according to the principle of ventilation psychrometer. It is equipped with two temperature sensors, one for dry bulb temperature measurement and the other for wet bulb temperature measurement. The wet bulb temperature sensor is wrapped with gauze soaked in water. The evaporation amount of the wet bulb surface of the humidity temperature sensor depends on the relative humidity of the atmosphere, and the heat required for evaporation causes a decrease in the temperature of the wet bulb. The relative humidity is calculated by the humidity formula based on the factors, such as dry bulb temperature, wet bulb temperature and atmospheric pressure at that time. The motor drives the fan to ventilate the surface of the dry and wet bulb temperature sensor, so that the surface of the sensor can maintain a substantially constant wind speed. Thus, the humidity measurement will be more stable and accurate.
| Model |
NM-HUMI700 |
| Temperature Range |
0℃~ 100℃ |
| Humidity Range |
10%RH ~ 99%RH |
| Temperature Resolution |
0.01℃ |
| Humidity Resolution |
0.01%RH |
| Temperature Accuracy |
≤ ±0.08℃ |
| Humidity Accuracy |
10%RH ~ 70%RH:±1.0%RH;大于 70%RH:±1.7%RH(20℃) |
| Temperature Transducer | Precision platinum resistance thermometer |
| Display | LCD |
| Precision Grade | Grade II humidity standard |
| Communication Interface | RS232 interface (optional) |
| Applicable Standards |
Verification Regulation of Mechanical Thermo - Hygrometers (JJG 205-2005) |
- 产品描述
-
- Commodity name: NM-HUMI700 Standard ventilation psychrometer
- Commodity ID: 1327233533134655488
Standard ventilation psychrometer is designed according to the principle of ventilation psychrometer. It is equipped with two temperature sensors, one for dry bulb temperature measurement and the other for wet bulb temperature measurement. The wet bulb temperature sensor is wrapped with gauze soaked in water. The evaporation amount of the wet bulb surface of the humidity temperature sensor depends on the relative humidity of the atmosphere, and the heat required for evaporation causes a decrease in the temperature of the wet bulb. The relative humidity is calculated by the humidity formula based on the factors, such as dry bulb temperature, wet bulb temperature and atmospheric pressure at that time. The motor drives the fan to ventilate the surface of the dry and wet bulb temperature sensor, so that the surface of the sensor can maintain a substantially constant wind speed. Thus, the humidity measurement will be more stable and accurate.
Product Overview
Standard ventilation psychrometer is designed according to the principle of ventilation psychrometer. It is equipped with two temperature sensors, one for dry bulb temperature measurement and the other for wet bulb temperature measurement. The wet bulb temperature sensor is wrapped with gauze soaked in water. The evaporation amount of the wet bulb surface of the humidity temperature sensor depends on the relative humidity of the atmosphere, and the heat required for evaporation causes a decrease in the temperature of the wet bulb. The relative humidity is calculated by the humidity formula based on the factors, such as dry bulb temperature, wet bulb temperature and atmospheric pressure at that time. The motor drives the fan to ventilate the surface of the dry and wet bulb temperature sensor, so that the surface of the sensor can maintain a substantially constant wind speed. Thus, the humidity measurement will be more stable and accurate.
Model NM-HUMI700
Temperature Range 0℃~ 100℃
Humidity Range 10%RH ~ 99%RH
Temperature Resolution 0.01℃
Humidity Resolution 0.01%RH
Temperature Accuracy ≤ ±0.08℃
Humidity Accuracy 10%RH ~ 70%RH:±1.0%RH;大于 70%RH:±1.7%RH(20℃)
Temperature Transducer Precision platinum resistance thermometer Display LCD Precision Grade Grade II humidity standard Communication Interface RS232 interface (optional) Applicable Standards Verification Regulation of Mechanical Thermo - Hygrometers (JJG 205-2005)
Verification Regulation of Electric Ventilation Psychrometers (JJG 993-2018)Key words:- Standard ventilation psychrometer
Production Equipment
If you are interested in this product, please fill in the following information and submit it to us, we will arrange professionals to contact us as soon as possible!
Related Products
Related Products