NM-01S Thermocouple and Thermal Resistance Manual / Semi-Automatic Calibration System
Key words:
Classification:
Product Description
Product Overview
The NM-01S thermocouple and thermal resistance manual calibration system consists of a manual switch, high-precision digital meter, dedicated cable signal line, calibration furnace, intelligent precision temperature control device, water (oil) bath, standard device, and ice point device. Users can select different constant temperature equipment and standards based on the temperature range of the sensor being tested. When equipped with a computer, communication card, and corresponding calibration software, it can automatically control the temperature of the constant temperature equipment, read the digital meter, process data, and generate and print tables during the calibration process, forming a semi-automatic calibration system.
The manual switch completes the switching of multi-channel tested and standard as well as reference end sensor signals, and also has the switching function that includes leads during three-wire resistance calibration.
The dedicated cable signal line connects the manual switch to the sensor, used to connect the standard device, reference end compensation sensor, and the sensor being tested.
Thermocouple and thermal resistance calibration system configuration table (single furnace, double furnace / multi-furnace, manual)
|
|
Product Selection |
NM-01 thermocouple and thermal resistance automatic calibration system |
NM-01Q thermocouple dual furnace (multi-furnace) thermal resistance automatic calibration system |
NM-01S thermocouple and thermal resistance manual/semi-automatic calibration system |
|
|
Function Description |
Calibration of second-class standard thermocouples, working thermocouples, industrial thermal resistances, industrial glass liquid thermometers, bimetallic thermometers, etc. |
Automatic calibration of various working thermocouples, industrial thermal resistances, industrial glass liquid thermometers, bimetallic thermometers, etc., can simultaneously control 1-8 calibration furnaces. |
Calibration of second-class standard thermocouples, working thermocouples, industrial thermal resistances, industrial glass liquid thermometers, bimetallic thermometers, etc. |
| Main Unit |
NM-01 low potential scanner/NM-ZJ01 three-wire resistance converter |
■ |
■ |
- |
| Manual Switch |
- |
- |
■ |
|
| Digital Multimeter |
■ |
■ |
■ |
|
| Reference End Sensor |
■ |
■ |
■ |
|
| Dedicated Calibration Software |
■ |
■ |
-/■ |
|
| Computer System |
■ |
■ |
□ |
|
| Printer |
■ |
■ |
□ |
|
| PCI Communication Interface |
■ |
■ |
-/■ |
|
| Supporting Equipment and Accessories |
NM-RTS series refrigeration constant temperature bath |
■ |
■ |
■ |
| NM-HTS95 constant temperature water bath |
□ |
□ |
□ |
|
| NM-HTS300 constant temperature oil bath |
■ |
■ |
■ |
|
| NM-HYC constant temperature salt bath |
□ |
□ |
□ |
|
| NM-JDL600 thermocouple calibration furnace |
■ |
■ |
■ |
|
| NM-JDL300 thermocouple calibration furnace |
□ |
□ |
□ |
|
| NM-JDL600H high-temperature thermocouple calibration furnace |
□ |
□ |
□ |
|
| NM-KW series intelligent temperature controller |
■ |
■ |
■ |
|
| NM-KT calibration furnace stand |
□ |
□ |
□ |
|
| NM-THL1000 thermocouple annealing furnace |
□ |
□ |
□ |
|
| NM-T1000 thermocouple cleaning and annealing device |
□ |
□ |
□ |
|
| NM-JW01 low metal thermocouple uniform temperature block |
□ |
□ |
□ |
|
| NM-JW02 armored thermocouple uniform temperature block |
□ |
□ |
□ |
|
| Freezer, ice crusher, ice bucket |
□ |
□ |
□ |
|
| Reference end thermostat (electronic ice point device) |
□ |
□ |
□ |
|
| NM-02 glass liquid thermometer reading device |
□ |
□ |
□ |
|
| Computer workstation chair |
■ |
■ |
□ |
|
| Accessories |
■ |
■ |
■ |
|
| Standard Device |
First-class / second-class standard thermocouples (S) |
■ |
■ |
■ |
| First-class / second-class standard thermocouples (B) |
□ |
□ |
□ |
|
| Second-class standard platinum resistance thermometer |
■ |
■ |
■ |
|
| Standard mercury thermometer |
□ |
□ |
□ |
Note:
1. The lower limit temperature of the low-temperature bath can be selected as -100℃, -80℃, -60℃, -40℃, -30℃, -10℃, 0℃.
2. The standard device is selected based on the model and accuracy level of the sensor being tested.
3. Digital multimeters can be selected from Keithley2010/2002, Agilent34401A /34420A, HY2030A, DMM7510, etc.
4. Multi-channel scanners can be selected for 8-channel or 10-channel tested channels.
5. An integrated temperature transmitter automatic calibration function can be selected.
■ indicates standard equipment
□ indicates optional equipment
- indicates no equipment needed.
- 产品描述
-
- Commodity name: NM-01S Thermocouple and Thermal Resistance Manual / Semi-Automatic Calibration System
The NM-01S thermocouple and thermal resistance manual calibration system consists of a manual switch, a high-precision digital meter, dedicated cable signal lines, a calibration furnace, an intelligent precision temperature control device, a water (oil) bath, a standard device, and a freezing point device.
Product Overview
The NM-01S thermocouple and thermal resistance manual calibration system consists of a manual switch, high-precision digital meter, dedicated cable signal line, calibration furnace, intelligent precision temperature control device, water (oil) bath, standard device, and ice point device. Users can select different constant temperature equipment and standards based on the temperature range of the sensor being tested. When equipped with a computer, communication card, and corresponding calibration software, it can automatically control the temperature of the constant temperature equipment, read the digital meter, process data, and generate and print tables during the calibration process, forming a semi-automatic calibration system.
The manual switch completes the switching of multi-channel tested and standard as well as reference end sensor signals, and also has the switching function that includes leads during three-wire resistance calibration.
The dedicated cable signal line connects the manual switch to the sensor, used to connect the standard device, reference end compensation sensor, and the sensor being tested.
Thermocouple and thermal resistance calibration system configuration table (single furnace, double furnace / multi-furnace, manual)
Product Selection
NM-01 thermocouple and thermal resistance automatic calibration system
NM-01Q thermocouple dual furnace (multi-furnace) thermal resistance automatic calibration system
NM-01S thermocouple and thermal resistance manual/semi-automatic calibration system
Function Description
Calibration of second-class standard thermocouples, working thermocouples, industrial thermal resistances, industrial glass liquid thermometers, bimetallic thermometers, etc.
Automatic calibration of various working thermocouples, industrial thermal resistances, industrial glass liquid thermometers, bimetallic thermometers, etc., can simultaneously control 1-8 calibration furnaces.
Calibration of second-class standard thermocouples, working thermocouples, industrial thermal resistances, industrial glass liquid thermometers, bimetallic thermometers, etc.
Main Unit
NM-01 low potential scanner/NM-ZJ01 three-wire resistance converter
■
■
-
Manual Switch
-
-
■
Digital Multimeter
■
■
■
Reference End Sensor
■
■
■
Dedicated Calibration Software
■
■
-/■
Computer System
■
■
□
Printer
■
■
□
PCI Communication Interface
■
■
-/■
Supporting Equipment and Accessories
NM-RTS series refrigeration constant temperature bath
■
■
■
NM-HTS95 constant temperature water bath
□
□
□
NM-HTS300 constant temperature oil bath
■
■
■
NM-HYC constant temperature salt bath
□
□
□
NM-JDL600 thermocouple calibration furnace
■
■
■
NM-JDL300 thermocouple calibration furnace
□
□
□
NM-JDL600H high-temperature thermocouple calibration furnace
□
□
□
NM-KW series intelligent temperature controller
■
■
■
NM-KT calibration furnace stand
□
□
□
NM-THL1000 thermocouple annealing furnace
□
□
□
NM-T1000 thermocouple cleaning and annealing device
□
□
□
NM-JW01 low metal thermocouple uniform temperature block
□
□
□
NM-JW02 armored thermocouple uniform temperature block
□
□
□
Freezer, ice crusher, ice bucket
□
□
□
Reference end thermostat (electronic ice point device)
□
□
□
NM-02 glass liquid thermometer reading device
□
□
□
Computer workstation chair
■
■
□
Accessories
■
■
■
Standard Device
First-class / second-class standard thermocouples (S)
■
■
■
First-class / second-class standard thermocouples (B)
□
□
□
Second-class standard platinum resistance thermometer
■
■
■
Standard mercury thermometer
□
□
□
Note:
1. The lower limit temperature of the low-temperature bath can be selected as -100℃, -80℃, -60℃, -40℃, -30℃, -10℃, 0℃.
2. The standard device is selected based on the model and accuracy level of the sensor being tested.
3. Digital multimeters can be selected from Keithley2010/2002, Agilent34401A /34420A, HY2030A, DMM7510, etc.
4. Multi-channel scanners can be selected for 8-channel or 10-channel tested channels.
5. An integrated temperature transmitter automatic calibration function can be selected.■ indicates standard equipment