NM-JY series thermal instrument calibration instrument
Key words:
Classification:
Product Description
Product Overview
The NM-JY series thermal instrument calibration device is a powerful and easy-to-use field calibration instrument. The measurement and simulation output functions can test and calibrate almost any process parameter except pressure. The series design of the instrument makes operation very simple. The choice of a dedicated casing allows for quick replacement of the self-supplied battery. When performing calibration, fault diagnosis, or maintenance, the NM-JY series calibration simulator will make your tasks easier.
Technical Parameters
| Model |
NM-JY04 |
NM-JY06 |
NM-JY06A |
| Accuracy |
0.02%FS |
0.02%FS |
0.01% reading +0.01% range |
| Voltage Measurement (V) |
-0.5~10.0000V |
0~30.000V |
-0.5~35.000V |
| Voltage Measurement (mV) |
0~±100.000mV |
0~100.00mV |
-5~500.00mV |
| Current Measurement |
0~22.0000mA |
0~24.000mA |
-5~55.000mA |
| Resistance Measurement |
0 ~ 4000.0Ω |
0~3200.0Ω |
0~5.5000KΩ |
| Frequency Measurement |
0.1~20000 Hz |
1~10000 Hz |
3~50.00000 KHz |
| Thermocouple Measurement and Output |
K, N, J, E, T, R, S, B |
||
| Thermoresistance Measurement and Output |
Pt10, Pt100, Pt1000, Cu50, Cu100 |
Pt100, Cu50 |
Pt100, Cu50 |
| Voltage Output (V) |
0~±10.0000V |
0~10.000V |
-0.1~11.000V |
| Voltage Output (mV) |
0~±100.000mV |
0~100.00mV |
-10~110.00mV |
| Current Output |
0~±22.0000mA |
0~24.000mA |
0~33.000mA |
| Resistance Output |
15 ~ 4000.0Ω |
15~3200.0Ω |
0 ~ 4.0000KΩ |
| 24V Output |
Yes |
Built-in 24V circuit measurement function |
Built-in 24V circuit measurement function |
| Dimensions (mm) |
260×320×85 |
223×96×55 |
223×96×55 |
| Others |
RS232 interface desktop |
4 rechargeable AA batteries, charger, handheld |
4 rechargeable AA batteries, charger, handheld, HART optional |
- 产品描述
-
- Commodity name: NM-JY series thermal instrument calibration instrument
The NM-JY series thermal instrument calibration device is a powerful and easy-to-use field calibration instrument. Its measurement and simulation output functions can test and calibrate almost any process parameter except for pressure.
Product Overview
The NM-JY series thermal instrument calibration device is a powerful and easy-to-use field calibration instrument. The measurement and simulation output functions can test and calibrate almost any process parameter except pressure. The series design of the instrument makes operation very simple. The choice of a dedicated casing allows for quick replacement of the self-supplied battery. When performing calibration, fault diagnosis, or maintenance, the NM-JY series calibration simulator will make your tasks easier.
Technical Parameters
Model
NM-JY04
NM-JY06
NM-JY06A
Accuracy
0.02%FS
0.02%FS
0.01% reading +0.01% range
Voltage Measurement (V)
-0.5~10.0000V
0~30.000V
-0.5~35.000V
Voltage Measurement (mV)
0~±100.000mV
0~100.00mV
-5~500.00mV
Current Measurement
0~22.0000mA
0~24.000mA
-5~55.000mA
Resistance Measurement
0 ~ 4000.0Ω
0~3200.0Ω
0~5.5000KΩ
Frequency Measurement
0.1~20000 Hz
1~10000 Hz
3~50.00000 KHz
Thermocouple Measurement and Output
K, N, J, E, T, R, S, B
Thermoresistance Measurement and Output
Pt10, Pt100, Pt1000, Cu50, Cu100
Pt100, Cu50
Pt100, Cu50
Voltage Output (V)
0~±10.0000V
0~10.000V
-0.1~11.000V
Voltage Output (mV)
0~±100.000mV
0~100.00mV
-10~110.00mV
Current Output
0~±22.0000mA
0~24.000mA
0~33.000mA
Resistance Output
15 ~ 4000.0Ω
15~3200.0Ω
0 ~ 4.0000KΩ
24V Output
Yes
Built-in 24V circuit measurement function
Built-in 24V circuit measurement function
Dimensions (mm)
260×320×85
223×96×55
223×96×55
Others
RS232 interface desktop
4 rechargeable AA batteries, charger, handheld
4 rechargeable AA batteries, charger, handheld, HART optional
Production Equipment
If you are interested in this product, please fill in the following information and submit it to us, we will arrange professionals to contact us as soon as possible!
Related Products
Related Products