NM-HTL series blackbody radiation source (spherical cavity)
NM-HTL series blackbody radiation source (spherical cavity)
+
  • NM-HTL series blackbody radiation source (spherical cavity)
  • NM-HTL series blackbody radiation source (spherical cavity)

NM-HTL series blackbody radiation source (spherical cavity)

The NM-HTL series blackbody radiation source uses PID control technology for temperature control, featuring high precision and good stability. The blackbody cavity is designed in a spherical shape with an emissivity greater than 0.998. Temperature calibration and correction are convenient, and the system also offers RS232/485 computer communication interfaces for easy computer control of temperature settings and automatic testing.

Key words:

Classification:

Product Description

Product Overview

The black body serves as a standard infrared radiation source, and its spectral energy can be obtained through calculations. It is suitable for calibration of infrared systems, determination of emissivity of various materials, measurement of infrared detector response rates, calibration of infrared thermometers, infrared thermal imagers, infrared remote sensing radiometers, and other instruments.

The NM-HTL series black body radiation source uses PID control technology for temperature control, featuring high precision and good stability. The black body cavity adopts a spherical design with an emissivity greater than 0.998. Temperature calibration and correction are convenient, and the system also has an RS232/485 computer communication interface available for selection, facilitating computer control for setting temperature and automatic testing.

Technical Parameters

 

Low Temperature Black Body

Medium Temperature Black Body

High Temperature Black Body

Model

NM-HTLN50Q

NM-HTLN30Q

NM-HTL700Q

NM-HTL1200Q

NM-HTL1600Q

Operating Temperature

-50℃ -100℃

-30℃ -100℃

35℃ -700℃

300℃ -1200℃

700℃ -1600℃

Cavity Diameter

Φ65mm

Φ65mm

Φ50mm

Φ50mm

Cavity Emissivity

>= 0.998

Temperature Resolution

0.01℃

Temperature Control Method

PID

3-Stage Temperature Control

Core Controller

Imported High-Precision Temperature Program Controller

Temperature Control Sensor

Pt100 Thermistor

K Thermocouple

S Thermocouple

3 B Thermocouples

Black Body Cavity Shape

Spherical Black Body Cavity

Temperature Stability

Not greater than (the larger of 0.1℃ and 0.1%t)

Temperature Uniformity

Not greater than ±(the larger of 0.15℃ and 0.15%t)

Power Supply

Single Phase 220VAC, 50Hz

Power (kW)

3.5

2.5

4

4

6.5

Weight (kg)

195

100

60

60

150

  • 产品描述
    • Commodity name: NM-HTL series blackbody radiation source (spherical cavity)

    The NM-HTL series blackbody radiation source uses PID control technology for temperature control, featuring high precision and good stability. The blackbody cavity is designed in a spherical shape with an emissivity greater than 0.998. Temperature calibration and correction are convenient, and the system also offers RS232/485 computer communication interfaces for easy computer control of temperature settings and automatic testing.

    Product Overview

    The black body serves as a standard infrared radiation source, and its spectral energy can be obtained through calculations. It is suitable for calibration of infrared systems, determination of emissivity of various materials, measurement of infrared detector response rates, calibration of infrared thermometers, infrared thermal imagers, infrared remote sensing radiometers, and other instruments.

    The NM-HTL series black body radiation source uses PID control technology for temperature control, featuring high precision and good stability. The black body cavity adopts a spherical design with an emissivity greater than 0.998. Temperature calibration and correction are convenient, and the system also has an RS232/485 computer communication interface available for selection, facilitating computer control for setting temperature and automatic testing.

    Technical Parameters

     

    Low Temperature Black Body

    Medium Temperature Black Body

    High Temperature Black Body

    Model

    NM-HTLN50Q

    NM-HTLN30Q

    NM-HTL700Q

    NM-HTL1200Q

    NM-HTL1600Q

    Operating Temperature

    -50℃ -100℃

    -30℃ -100℃

    35℃ -700℃

    300℃ -1200℃

    700℃ -1600℃

    Cavity Diameter

    Φ65mm

    Φ65mm

    Φ50mm

    Φ50mm

    Cavity Emissivity

    >= 0.998

    Temperature Resolution

    0.01℃

    Temperature Control Method

    PID

    3-Stage Temperature Control

    Core Controller

    Imported High-Precision Temperature Program Controller

    Temperature Control Sensor

    Pt100 Thermistor

    K Thermocouple

    S Thermocouple

    3 B Thermocouples

    Black Body Cavity Shape

    Spherical Black Body Cavity

    Temperature Stability

    Not greater than (the larger of 0.1℃ and 0.1%t)

    Temperature Uniformity

    Not greater than ±(the larger of 0.15℃ and 0.15%t)

    Power Supply

    Single Phase 220VAC, 50Hz

    Power (kW)

    3.5

    2.5

    4

    4

    6.5

    Weight (kg)

    195

    100

    60

    60

    150

Production Equipment


If you are interested in this product, please fill in the following information and submit it to us, we will arrange professionals to contact us as soon as possible!

Related Products

Related Products