NM-JDL Series Medium-temperature Thermocouple Calibration Furnace
Number of views:
1000

NM-JDL Series Medium-temperature Thermocouple Calibration Furnace

NM-JDL Series Thermocouple Calibration Furnace is mainly used for the verification/calibration of base metal thermocouples (types K, E, J and N), working noble metal thermocouples (types S and R) and standard thermocouples (types S and R) within the temperature range of 300-1,200℃. 
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
产品介绍
Parameters
NM-JDL Series Medium-temperature Thermocouple Calibration Furnace NM-JDL Series Medium-temperature Thermocouple Calibration Furnace

 

Product Overview

NM-JDL Series Thermocouple Calibration Furnace is mainly used for the verification/calibration of base metal thermocouples (types K, E, J and N), working noble metal thermocouples (types S and R) and standard thermocouples (types S and R) within the temperature range of 300-1,200℃. 

The main technical indicators of the products meet the requirements of relevant verification regulations and Testing Specification of Temperature Uniformity in Thermocouple Calibration Furnaces (JJF1184-2007). 

1. Application of Thermocouple Calibration Furnace 

NM-JDL600A Thermocouple Calibration Furnace is mainly used for the calibration of working base metal thermocouples (types K, E, J and N) and working noble metal thermocouples (types S and R) within the temperature range of 300-1,2000℃. 

According to the national metrological verification regulation of thermocouples, the maximum uniform temperature range of the calibration furnace is widened to ensure the accuracy of calibration. 

2. Verification regulations for thermocouple calibration furnace 

Verification Regulation of Base Metal Thermocouples (JJG 351-1996)

Verification Regulation of Working Noble Metal Thermocouples (JJG 141-2000)

Testing Specification of Temperature Uniformity in Thermocouple Calibration Furnaces (JJF 1184-2007)

3. Main technical indicators of thermocouple calibration furnace 

3.1 Furnace size:Φ40×600mm

3.2 Operating temperature:300~1200oC

3.3 Rated power: 220VAC,3.5KW

3.4 Allowable heating rate:≤40℃/min

3.5 Temperature field distribution: the axial deviation between the highest uniform temperature field center and the geometric center of the calibration furnace shall not be more than 10mm, the length of the uniform temperature field shall not be less than 60mm, and the temperature difference within the radius of 14mm shall be ≤1℃. 

4. Installation and use of thermocouple calibration furnace 

4.1 The temperature control thermocouple is inserted into the left side of the furnace, and the standard and calibrated thermocouples are inserted from the right side; 

4.2 In case of unstable temperature control due to unstable power supply or interference of the system, a 5KVA AC purification power supply shall be added. 

4.3 First, install and connect the standard thermocouple and the calibrated thermocouple, and then turn on the main power switch for power-on operation. 

4.4 By adjusting the maximum output power limit of the thermocouple calibration furnace control system or other temperature control equipment, the heating speed of the calibration furnace is limited within 40℃/min during the heating process to prevent equipment damage caused by excessive temperature rise. 

4.5 During automatic calibration, the computer automatically controls the parameter modification and operation of the instrument and the heating process of the calibration furnace. 

5. Precautions for thermocouple calibration furnace 

5.1 The furnace shall be kept clean inside. After the thermocouple is installed, the furnace mouth shall be blocked with refractory materials. 

5.2 When the calibration furnace is used for the first time, the furnace temperature shall be increased to about 500℃, and the furnace can be used after drying for 2 hours at the constant temperature. 

5.3 When the calibration furnace lies idle for a long time, it shall be stored in a dry and ventilated place. It shall be dried before reused.

5.4 For safety, the calibration furnace must be reliably grounded and the power supply must be connected to 220V AC 16A. 

Technical Parameters

Product Model

NM-JDL300

NM-JDL600

Temperature Range

300℃~ 1200℃

300℃~ 1200℃

Uniformity of Temperature Field The axial deviation between the highest uniform temperature field center and the geometric center shall be ≤10mm, the length shall not be less than 40mm, and the temperature difference shall be ≤1℃.  Within 30mm in the axial direction of the effective working area, the absolute value of temperature difference between any two points shall not be more than 0.5℃; within the range of radial radius not less than 14mm, the absolute value of temperature difference between any two points on the same section shall not be more than 0.25℃. 
Furnace Size

Ф40×300mm

Ф40×600mm

Overall Dimensions

320×240×330mm

620×300×360mm

Power Supply Power 

220VAC、4.5kW

220VAC、3kW

Weight

15kg

20kg

 

Keyword:
NM-JDL
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table
What are the precautions for using a precision dew point meter?
The precision dew point meter adopts the world's advanced sensor technology, the new sensor of British ALPHA company, it adopts DRYCAP-film sensing technology and humidity-sensitive material, and has three world patents: polyester film probe DRYCAP. Resistant to condensation, dust particles, resistant to gasoline and most gases, ideal for industrial environments with low dew points and controlled dry points. Precautions for the use of the precision dew point meter, the instrument should be placed in a safe location to prevent damage. Avoid violent vibrations. Do not measure corrosive gases. The probe should be cleaned and calibrated after a certain period of time, and the calibration cycle should be one year.
See more information 白箭头 黑箭头
Sharing of functions and features of precision dew point meter
Precision dew point meter, also known as dew point meter, micro water meter, SF6 micro water meter, intelligent micro water meter, SF6 gas micro water meter, SF6 precision dew point meter, etc., is an ideal choice for industrial environments with low dew point and dry point control.
See more information 白箭头 黑箭头
The Importance of Moisture Measurement with Precision Dew Point Meters
Precision dew point meter refers to a mirror dew point meter with semiconductor refrigeration and photoelectric automatic balance. Relative humidity is the percentage of the mole fraction of water vapor in the measured environment to the mole fraction of saturated water vapor at the same temperature and pressure, that is, the ratio of the partial pressure of water vapor in the environment to the saturated water vapor pressure at the same temperature (water vapor in the air). is equal to the saturated water vapor pressure at the dew point temperature). The precision dew point meter measures relative humidity by measuring dew point and ambient temperature, so relative humidity has two uncertain factors: the uncertainty of dew point and ambient temperature measurement.
See more information 白箭头 黑箭头
The working principle of constant temperature bath and the introduction of two major control systems
The low temperature thermostat is widely used in chemical, petroleum, medicine, biology, physical chemistry, metrology, universities, electronic instruments, scientific research institutions and other fields for experiments. In order to meet the requirements of the constant temperature environment for the main components of the LPG density meter Large, size φ260 × 420, mixing area φ160 × 420, total volume 34 liters, other properties are: working temperature range 10 ° c ~ 95 ° c, working ambient temperature less than 30 ° c, total power 3kw, power 220v/50hz, Can work in ordinary laboratories.
See more information 白箭头 黑箭头
What are the components of a constant temperature bath? how to choose?
What are the components of a constant temperature bath? how to choose? Many companies use thermostatic baths in their daily work, but many people do not know what parts of the thermostatic bath are made of and which parts are more important. Too careful comparison. Today, we will take you a detailed understanding of the components of the thermostatic bath, so that you can know what structures this product has.
See more information 白箭头 黑箭头
Tell everyone about the product features of the low temperature thermostat
In the laboratory, we often encounter situations where the experimental sample needs to be kept at a specific ambient temperature, a low temperature constant temperature or a high temperature constant temperature. In the high temperature constant temperature, we often use a high temperature constant temperature oil bath, because the boiling point of the oil is very high, if It is in water, you can use constant temperature water bath, constant temperature water bath, low temperature constant temperature tank and other instruments, the constant temperature effect of these instruments in water is very significant, if you need a low temperature and constant temperature state, generally use a low temperature constant temperature tank, which can not only maintain low temperature, but also with With the advancement of technology, the accuracy will also improve under constant temperature conditions.
See more information 白箭头 黑箭头
Nimeng Technology

Follow Nimeng Electronics

Taian Nimeng Electronic Technology Co., Ltd.

Hotline:+86-400-646-8801 

Tel:+865388588768

Fax:+865388588769  

E-Mail:tanimeng@126.com
Address: East of Panhe Street, Taishan District, Tai'an City, Shandong Province

版权信息

Time of issue:2020-11-20 09:05:16

Copyright © Taian Nimeng Electronic Technology Co.,Ltd. 鲁ICP备11009995号 Powered by www.300.cn