NM-01S Manual / Semi-automatic Calibration System of Thermocouples and Resistance Thermometers
Product Overview
NM-01S Manual Calibration System of Thermocouples and Resistance Thermometers is mainly composed of a manual switch, a high-precision digital meter, a special cable signal line, a calibration furnace, an intelligent precision temperature control device, a water (oil) bath, a calibrator and a freezing point detector. The user can select different thermostatic equipment and calibrators according to the temperature range of the calibrated sensor. The system is equipped with a computer, a communication card and the corresponding calibration software. It can automatically control the temperature of the thermostatic equipment, read the digital meter, process the data and print the form in the calibration process, forming a semi-automatic calibration system.
The manual switch completes the switching of signals of multi-channel calibrated and standard and reference end sensors, with the switching function including the lead wire during the calibration of three-wire resistance thermometer.
The special cable signal line is the connecting line between the manual switch and the sensor, which is used to connect the calibrator, the reference end compensation sensor and the calibrated sensor.
Configuration Table of Thermocouple and Resistance Thermometer Calibration System (Single-furnace, Double-furnace / Group-furnace, Manual)
|
Product model selection | NM-01 Automatic Calibration System of Thermocouples and Resistance Thermometers | NM-01Q Automatic Calibration System of Thermocouples and Double-furnace (Group-furnace) Resistance Thermometers | NM-01S Manual / Semi-automatic Calibration System of Thermocouples and Resistance Thermometers: |
|
Function description
|
Calibrate the second-class standard thermocouple, working thermocouple, industrial resistance thermometer, industrial liquid-in-glass thermometer, bimetallic thermometer, etc. | Automatically verify various working thermocouples, industrial resistance thermometers, industrial liquid-in-glass thermometers, bimetallic thermometers, etc., and control 1-8 calibration furnaces at the same time. | Calibrate the second-class standard thermocouple, working thermocouple, industrial resistance thermometer, industrial liquid-in-glass thermometer, bimetallic thermometer, etc. |
Main Machine |
NM-01 Low Potential Scanner / Manual Switch |
■ |
■ |
■ |
NM-ZJ01 Three-wire Resistance Converter |
■ |
■ |
— |
|
Digital multimeter |
■ |
■ |
■ |
|
Reference end sensor |
■ |
■ |
■ |
|
Special calibration software |
■ |
■ |
□ |
|
Computer system |
■ |
■ |
□ |
|
Printer |
■ |
■ |
□ |
|
PCI communication interface |
■ |
■ |
□ |
|
Supporting Equipment and Accessories |
NM-RTS Series Cooling Thermostatic Bath |
■ |
■ |
■ |
NM-HTS95 Thermostatic Water Bath |
□ |
□ |
□ |
|
NM-HTS300 Thermostatic Oil Bath |
■ |
■ |
■ |
|
NM-HYC Thermostatic Salt Bath |
□ |
□ |
□ |
|
NM-JDL600 Thermocouple Calibration Furnace |
■ |
■ |
■ |
|
NM-JDL300 Thermocouple Calibration Furnace |
□ |
□ |
□ |
|
NM-JDL600H High-temperature Thermocouple Calibration Furnace |
□ |
□ |
□ |
|
NM-KW Series Intelligent Temperature Controller |
■ |
■ |
■ |
|
NM-KT Calibration Furnace Rack |
□ |
□ |
□ |
|
NM-THL1000 Thermocouple Annealing Furnace |
□ |
□ |
□ |
|
NM-T1000 Thermocouple Cleaning Annealing Device |
□ |
□ |
□ |
|
NM-JW01 Base Metal Thermocouple Equalizing Block |
□ |
□ |
□ |
|
NM-JW02 Sheathed Thermocouple Equalizing Block |
□ |
□ |
□ |
|
Freezer, ice crusher, ice bucket |
□ |
□ |
□ |
|
Reference end thermostat (electronic freezing point detector) |
□ |
□ |
□ |
|
NM-02 Liquid-in-glass Thermometer Reader Unit |
□ |
□ |
□ |
|
Computer workbench chair |
■ |
■ |
□ |
|
Appendix |
■ |
■ |
■ |
|
Calibrator | First-class / Second-class standard thermocouple (S) |
■ |
■ |
■ |
First-class / Second-class standard thermocouple (B) |
□ |
□ |
□ |
|
Second-class standard platinum resistance thermometer |
■ |
■ |
■ |
|
Standard mercurial thermometer |
□ |
□ |
□ |
■Indicating standard equipment
□Indicating optional equipment
—Indicating no need for equipment
Remarks: 1. Lower limit temperature of low temperature bath (optional): -100℃, -80℃, -60℃, -40℃, -30℃, -10℃, 0℃.
2. The calibrator shall be selected according to the model and accuracy level of the calibrated sensor.
3. Digital multimeter (optional): Keithley2000/2010/2002, Agilent34401A/34420A, etc.
4. 8 channels and 10 channels can be selected for calibration with the multi-channel scanner.