PRODUCTS
-
Measurement calibration of temperature sensor
-
Measurement calibration of temperature and humidity test equipment
-
Measurement calibration of temperature and humidity indicator (meter)
-
Measurement calibration of surface thermometer
-
Measurement calibration of radiation thermometer
-
Measurement calibration of thermometer
-
Measurement calibration of temperature secondary instrument
-
Pressure measurement calibration
-
Other thermal metering equipment
NM-01Q Automatic Calibration System of Thermocouples and Double-furnace / Group-furnace Resistance Thermometers
Product Overview
NM-01Q Automatic Calibration System of Thermocouples and Double-furnace / Group-furnace Resistance Thermometers is mainly composed of a computer, a double-furnace multi-channel scanner, a high-precision digital meter, a three-wire resistance converter / junction board, a calibration furnace, an intelligent precision temperature control device, a water (oil) bath, a calibrator and a freezing point detector. The user can select different thermostatic equipment and calibrators according to the temperature range of the calibrated sensor.
The system takes computer as the core, controls the multi-channel scanner, the digital meter and the constant temperature equipment. It automatically completes the calibration work of thermocouple from 1# furnace to 8# furnace.
For each furnace, 8 or 10 thermocouples can be calibrated at a time. Each set of scanning system (multi-channel scanner and three-wire junction board) can be connected to 2 furnaces for calibration of double furnace at the same time. It can be expanded and customized according to user needs.
Configuration Table of Thermocouple and Resistance Thermometer Calibration System (Single-furnace, Double-furnace / Group-furnace, Manual)
|
Product model selection | NM-01 Automatic Calibration System of Thermocouples and Resistance Thermometers | NM-01Q Automatic Calibration System of Thermocouples and Double-furnace (Group-furnace) Resistance Thermometers | NM-01S Manual / Semi-automatic Calibration System of Thermocouples and Resistance Thermometers: |
|
Function description
|
Calibrate the second-class standard thermocouple, working thermocouple, industrial resistance thermometer, industrial liquid-in-glass thermometer, bimetallic thermometer, etc. | Automatically verify various working thermocouples, industrial resistance thermometers, industrial liquid-in-glass thermometers, bimetallic thermometers, etc., and control 1-8 calibration furnaces at the same time. | Calibrate the second-class standard thermocouple, working thermocouple, industrial resistance thermometer, industrial liquid-in-glass thermometer, bimetallic thermometer, etc. |
Main Machine |
NM-01 Low Potential Scanner / Manual Switch |
■ |
■ |
■ |
NM-ZJ01 Three-wire Resistance Converter |
■ |
■ |
— |
|
Digital multimeter |
■ |
■ |
■ |
|
Reference end sensor |
■ |
■ |
■ |
|
Special calibration software |
■ |
■ |
□ |
|
Computer system |
■ |
■ |
□ |
|
Printer |
■ |
■ |
□ |
|
PCI communication interface |
■ |
■ |
□ |
|
Supporting Equipment and Accessories |
NM-RTS Series Cooling Thermostatic Bath |
■ |
■ |
■ |
NM-HTS95 Thermostatic Water Bath |
□ |
□ |
□ |
|
NM-HTS300 Thermostatic Oil Bath |
■ |
■ |
■ |
|
NM-HYC Thermostatic Salt Bath |
□ |
□ |
□ |
|
NM-JDL600 Thermocouple Calibration Furnace |
■ |
■ |
■ |
|
NM-JDL300 Thermocouple Calibration Furnace |
□ |
□ |
□ |
|
NM-JDL600H High-temperature Thermocouple Calibration Furnace |
□ |
□ |
□ |
|
NM-KW Series Intelligent Temperature Controller |
■ |
■ |
■ |
|
NM-KT Calibration Furnace Rack |
□ |
□ |
□ |
|
NM-THL1000 Thermocouple Annealing Furnace |
□ |
□ |
□ |
|
NM-T1000 Thermocouple Cleaning Annealing Device |
□ |
□ |
□ |
|
NM-JW01 Base Metal Thermocouple Equalizing Block |
□ |
□ |
□ |
|
NM-JW02 Sheathed Thermocouple Equalizing Block |
□ |
□ |
□ |
|
Freezer, ice crusher, ice bucket |
□ |
□ |
□ |
|
Reference end thermostat (electronic freezing point detector) |
□ |
□ |
□ |
|
NM-02 Liquid-in-glass Thermometer Reader Unit |
□ |
□ |
□ |
|
Computer workbench chair |
■ |
■ |
□ |
|
Appendix |
■ |
■ |
■ |
|
Calibrator | First-class / Second-class standard thermocouple (S) |
■ |
■ |
■ |
First-class / Second-class standard thermocouple (B) |
□ |
□ |
□ |
|
Second-class standard platinum resistance thermometer |
■ |
■ |
■ |
|
Standard mercurial thermometer |
□ |
□ |
□ |
■Indicating standard equipment
□Indicating optional equipment
—Indicating no need for equipment
Remarks: 1. Lower limit temperature of low temperature bath (optional): -100℃, -80℃, -60℃, -40℃, -30℃, -10℃, 0℃.
2. The calibrator shall be selected according to the model and accuracy level of the calibrated sensor.
3. Digital multimeter (optional): Keithley2000/2010/2002, Agilent34401A/34420A, etc.
4. 8 channels and 10 channels can be selected for calibration with the multi-channel scanner.