NM-05 Temperature and Humidity Uniformity Test System
Number of views:
1000

NM-05 Temperature and Humidity Uniformity Test System

NM-05 Temperature and Humidity Uniformity Test System is composed of notebook computer, multi-channel data acquisition unit or high-precision digital measuring instrument with multi-channel conversion function, which is easy to carry. The system takes the computer system as the core, uses thermocouple or resistance thermometer as the temperature measuring component. It can be used for multi-channel temperature and humidity measurement, so as to realize the test of temperature and humidity field uniformity and fluctuation of temperature and humidity equipment, such as temperature and humidity test chamber and heat treating furnace. The test process and result processing of the system all comply with relevant current national standards. 
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
产品介绍
Parameters

Product Overview

NM-05 Temperature and Humidity Uniformity Test System is composed of notebook computer, multi-channel data acquisition unit or high-precision digital measuring instrument with multi-channel conversion function, which is easy to carry. The system takes the computer system as the core, uses thermocouple or resistance thermometer as the temperature measuring component. It can be used for multi-channel temperature and humidity measurement, so as to realize the test of temperature and humidity field uniformity and fluctuation of temperature and humidity equipment, such as temperature and humidity test chamber and heat treating furnace. The test process and result processing of the system all comply with relevant current national standards. 

Product function

It can automatically complete the data acquisition, data processing, display and printing of test results of temperature uniformity test for heat treating furnace and temperature & humidity test for temperature & humidity environment test equipment.
It can automatically compensate the reference end and correct the sensor calibration data. 

Types S, R, B, J, K, N, E and T thermocouples can be used for temperature uniformity test for heat treating furnace and box type resistance furnace. The test method and requirements comply with Testing Method for Working Zone of Heat Treating Furnace (GB/T 9452-2012) and Calibration Specification for Box-type Resistance Furnace (JJF 1376-2012). 

For the test of temperature & humidity environment test equipment, PT100 resistance thermometer or T-type thermocouple is used for temperature measurement, and dry and wet bulb or imported humidity sensor is used for humidity measurement. 

The test method and requirements comply with Calibration Specification for the Equipment of the Environmental Testing for Temperature and Humidity (JJF 1101-2019). 

Product Features

★ The hardware configuration is flexible. NM-05 series multi-channel data acquisition unit of the Company or imported data acquisition unit can be used. It is of simple structure and easy to carry with high reliability. 
★ It is compatible with the wiring of thermocouple and four-wire resistance thermometer. Products of some models support channel expansion. 
★ During the test of the heat treating furnace, the treatment of the reference end allows freezing point compensation, external sensor compensation or actual temperature compensation of the reference end. 
★ During the test process, the system automatically draws the temperature curve (temperature-time relation curve). The curve will be dynamically displayed and refreshed with the progress of the test process, and can be enlarged and reduced in real time. For the calibration of alternating damp heat equipment, it can also automatically draw the temperature and humidity characteristic curves. 
★ The system supports setting of temperature and humidity data of each channel for regular patrol inspection, and form patrol inspection data records and curves to reflect the temperature and humidity changes at each position during equipment test. 
★ In the course of calculating the test data, the sensor certificate value is added to correct the data, so as to improve the test accuracy. 
★ The system automatically saves test data and results on the hard disk in the form of database, so that users can easily query the data. 
★ The system supports simulation runs. Without external equipment, the test process can be directly simulated on the computer. 
★ It has the function of continuous running in case of power down. During the test, if a sudden power failure occurs or the program exits for some reason, the test can be continued with the completed data. 

System Configuration Plan 

  

 

Plan 1 Plan 2 

Plan 3

Hardware Configuration NM-05A Multi-channel Data Acquisition Unit  (Keithley2700)多通道数据采集卡(Keithley7700)
NM-05B Temperature & Humidity Data Acquisition System 
6-bit Half Data Acquisition Unit  (Keithley 2700), Multi-channel Data Acquisition Card (Keithley 7700) 

NM-05 Temperature and Humidity Uniformity Test System

Sensor Configuration HC2-S
Special test thermocouple: Type K Class I, special test resistance thermometer: Pt100A, humidity sensor: HC2-S
Special test thermocouple: Type K Class I, special test resistance thermometer: Pt100A, humidity sensor: HC2-S Special test thermocouple: Type K Class I, special test resistance thermometer: Pt100A, humidity sensor: HC2-S
Number of Channels  24 channels (channels 1-20 are for temperature, and channels 21-24 are for humidity) A single card can complete signal measurement of 20-channel thermocouple or 10-channel resistance thermometer. The user can choose 2 cards.  24 channels (channels 1-20 are for temperature, and channels 21-24 are for humidity)
Performance Index

 

Resolution: 

Resistance thermometer: 0.01℃

Thermocouple: 0.1℃±0.02%FS/±0.05%FS
Measurement accuracy: ±0.02%FS/±0.05%FS

Resolution: 
Thermocouple: 0.001℃ (K, N, J, E, T) 0.1℃ (S, R, B) 
Resistance thermometer: 0.01℃
Accuracy: 
Thermocouple: 0.2℃ (K, N, J, E, T) 0.6℃ (S, R, B) 
Resistance thermometer: 0.06℃ (Pt100 platinum resistance thermometer)
Resolution: 
Resistance thermometer: 0.01℃
Thermocouple: 0.1℃
Measurement accuracy: ±0.02%FS
Computer, system test software and communication interface are integrated as one. 
Optional Configuration Laptops
System software
Communication interface
Laptops
System software
Communication interface
ortable box, printer 

 

Keyword:
NM-05
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table
Previous
Next
What are the precautions for using a precision dew point meter?
The precision dew point meter adopts the world's advanced sensor technology, the new sensor of British ALPHA company, it adopts DRYCAP-film sensing technology and humidity-sensitive material, and has three world patents: polyester film probe DRYCAP. Resistant to condensation, dust particles, resistant to gasoline and most gases, ideal for industrial environments with low dew points and controlled dry points. Precautions for the use of the precision dew point meter, the instrument should be placed in a safe location to prevent damage. Avoid violent vibrations. Do not measure corrosive gases. The probe should be cleaned and calibrated after a certain period of time, and the calibration cycle should be one year.
See more information 白箭头 黑箭头
Sharing of functions and features of precision dew point meter
Precision dew point meter, also known as dew point meter, micro water meter, SF6 micro water meter, intelligent micro water meter, SF6 gas micro water meter, SF6 precision dew point meter, etc., is an ideal choice for industrial environments with low dew point and dry point control.
See more information 白箭头 黑箭头
The Importance of Moisture Measurement with Precision Dew Point Meters
Precision dew point meter refers to a mirror dew point meter with semiconductor refrigeration and photoelectric automatic balance. Relative humidity is the percentage of the mole fraction of water vapor in the measured environment to the mole fraction of saturated water vapor at the same temperature and pressure, that is, the ratio of the partial pressure of water vapor in the environment to the saturated water vapor pressure at the same temperature (water vapor in the air). is equal to the saturated water vapor pressure at the dew point temperature). The precision dew point meter measures relative humidity by measuring dew point and ambient temperature, so relative humidity has two uncertain factors: the uncertainty of dew point and ambient temperature measurement.
See more information 白箭头 黑箭头
The working principle of constant temperature bath and the introduction of two major control systems
The low temperature thermostat is widely used in chemical, petroleum, medicine, biology, physical chemistry, metrology, universities, electronic instruments, scientific research institutions and other fields for experiments. In order to meet the requirements of the constant temperature environment for the main components of the LPG density meter Large, size φ260 × 420, mixing area φ160 × 420, total volume 34 liters, other properties are: working temperature range 10 ° c ~ 95 ° c, working ambient temperature less than 30 ° c, total power 3kw, power 220v/50hz, Can work in ordinary laboratories.
See more information 白箭头 黑箭头
What are the components of a constant temperature bath? how to choose?
What are the components of a constant temperature bath? how to choose? Many companies use thermostatic baths in their daily work, but many people do not know what parts of the thermostatic bath are made of and which parts are more important. Too careful comparison. Today, we will take you a detailed understanding of the components of the thermostatic bath, so that you can know what structures this product has.
See more information 白箭头 黑箭头
Tell everyone about the product features of the low temperature thermostat
In the laboratory, we often encounter situations where the experimental sample needs to be kept at a specific ambient temperature, a low temperature constant temperature or a high temperature constant temperature. In the high temperature constant temperature, we often use a high temperature constant temperature oil bath, because the boiling point of the oil is very high, if It is in water, you can use constant temperature water bath, constant temperature water bath, low temperature constant temperature tank and other instruments, the constant temperature effect of these instruments in water is very significant, if you need a low temperature and constant temperature state, generally use a low temperature constant temperature tank, which can not only maintain low temperature, but also with With the advancement of technology, the accuracy will also improve under constant temperature conditions.
See more information 白箭头 黑箭头
Nimeng Technology

Follow Nimeng Electronics

Taian Nimeng Electronic Technology Co., Ltd.

Hotline:+86-400-646-8801 

Tel:+865388588768

Fax:+865388588769  

E-Mail:tanimeng@126.com
Address: East of Panhe Street, Taishan District, Tai'an City, Shandong Province

版权信息

Time of issue:2020-11-20 09:05:16

Copyright © Taian Nimeng Electronic Technology Co.,Ltd. 鲁ICP备11009995号 Powered by www.300.cn