Temperature and Humidity Calibration Box: Introduction of Temperature and Humidity Calibration Box
- Categories:News
- Author:
- Origin:
- Time of issue:2021-04-28
- Views:0
(Summary description)The temperature and humidity test box is used to detect hair High-precision temperature and humidity field equipment for temperature and humidity meters (meters), bimetal temperature and humidity meters and other types of temperature and humidity sensors can also be used for high-precision constant temperature and humidity test projects.
Temperature and Humidity Calibration Box: Introduction of Temperature and Humidity Calibration Box
(Summary description)The temperature and humidity test box is used to detect hair High-precision temperature and humidity field equipment for temperature and humidity meters (meters), bimetal temperature and humidity meters and other types of temperature and humidity sensors can also be used for high-precision constant temperature and humidity test projects.
- Categories:News
- Author:
- Origin:
- Time of issue:2021-04-28
- Views:0
1.Temperature and humidity test boxProduct Introduction
The temperature and humidity test box is used to detect hair High-precision temperature and humidity field equipment for temperature and humidity meters (meters), bimetal temperature and humidity meters and other types of temperature and humidity sensors can also be used for high-precision constant temperature and humidity test projects.
The cabinet is made of stainless steel, The outer layer is sprayed to ensure beautiful appearance and corrosion resistance; the control sensor adopts Rodronic humidity sensor and imported temperature sensor, with high precision and good reliability; PIDparameter self-tuning function, which ensures fast and stable system balance; The control interface adopts an advanced touch control screen, which is easy to operate, flexible and powerful, and can realize continuous tests for several days.
2.Temperature and Humidity Test Box How it works
1, Humidification: ExpertPIDRegulator controls saturated moisture The injection amount reaches equilibrium.
2, Dehumidification: Forcing moisture to flow through the condenser to form water condensation to achieve the purpose of dehumidification.
3, Temperature control: The isothermal water circulation technology is used to control the overall temperature field to achieve an excellent temperature field.
3.Temperature and Humidity Test Box Technical Parameters
Model |
NM-HWS03 |
use ambient temperature |
20±5℃ |
Temperature Range |
5°C~50°C (can be expanded according to usage needs, -20~80°C)< /p> |
Humidity range |
25%RH~95%RH |
Temperature fluctuation |
≤±0.1℃ (15℃, 20℃, 30℃) |
Temperature Uniformity |
≤0.3℃ (measured at 15℃, 20℃, 30℃)< /p> |
Humidity Fluctuation |
≤±0.8%RH(20℃) |
Humidity uniformity |
≤1.0%RH(20℃) |
Temperature system |
Isothermal hot plate heating, cooling/expert PID adjustment, platinum resistance sensor measurement control |
humidity control system |
Accurately control the ratio of dry and wet gas to form different wet fields, and temperature and humidity sensor measurement control |
Shell Material |
High-quality 304 stainless steel jacket with spray treatment |
Viewer |
The studio is tempered with tempered glass on three sides; 2 operation holes |
Temperature and humidity measurement method |
Electric ventilation psychrometer, humidity sensor or precision dew point meter |
Control mode |
Touch screen man-machine interface, fully automatic control All kinds of control, setting, protection, curve display and other parameters are readily available Timer switch can be set, with wind speed variable frequency adjustment function Control state programmable The corresponding equipment can be installed to form an automatic test, and the test task can be completed in the unmanned state |
Studio Internal Size |
500㎜ ×500㎜×500㎜(500 ㎜×800㎜× ;800㎜can be customized) |
Dimensions (height/width/thickness) |
1700㎜×700㎜×1000㎜( 1700㎜×1000㎜×1300㎜) |
Weight |
about 350kg |
Applicable Standards |
"Mechanical Thermo-Hygrometer" Verification Regulations (JJG205-2005) "Temperature and Humidity Standard Chamber" Calibration Specification (JJF1564-2016) |
4.Temperature and Humidity Test Box Notes
1, The dirt on the transducer of the humidifier will affect the air volume. The transducer of the humidifier should be cleaned regularly with a special cleaning solution.
2, Check whether the humidifier is short of water.
3, Check the liquid level of the temperature control tank. If it is too low, the medium should be replenished in time to avoid burning out the humidifier
4, Check for gaps in doors or operating holes.
5, Running under high humidity, there will be water droplets in the box, which is a normal phenomenon.
6、The compressor will not be turned on for 5 minutes when the compressor is turned off5. (with compressor protection function)
7、When measuring temperature, if the humidity in the box is higher than 80%RH,It is recommended to set the humidity at 60%RH.
8、The test box should be grounded reliably.
5.Temperature and Humidity Test Box Troubleshooting
Symptoms |
Cause of failure |
Exclusion method |
Humidity display length 、Time is fixed |
Humidity sensor failure or dehumidification compressor Fault |
Please contact the supplier to resolv |
Humidity display does not rise
|
Humidifier off |
Turn on humidifier
|
The temperature display does not rise
|
Temperature control module damaged
|
replace
|
Heating tube damaged
|
replace |
Scan the QR code to read on your phone
Follow Nimeng Electronics
Taian Nimeng Electronic Technology Co., Ltd.
Hotline:+86-400-646-8801
Tel:+865388588768
Fax:+865388588769
E-Mail:tanimeng@126.com
Address: No. 5, Wuma Street, Shanggao Street, Taishan District, Tai'an City, Shandong Province, China
版权信息
Copyright © Taian Nimeng Electronic Technology Co.,Ltd. 鲁ICP备11009995号 Powered by www.300.cn